When designing a hot water system for kitchen needs at a restaurant, the designer should note that both 140ºF and 180ºF temperature water is required. An ample supply of 180ºF is used for the final rinse on many automatic dishwashers available today and the 140ºF supply of water is used for general cleaning and food preparation. The main concern when sizing a hot water system for a restaurant is supplying adequate hot water to maintain sanitation requirements.
Special Design Considerations
General "Rules of Thumb" For Sizing
| Food service establishments | Max. hour | Max. Day | Avg. Day |
| Type "A" | |||
| Full meal restaurant/cafeterias | 1.5 gal/max. meal/hour |
11.0 gal/max. meal/hour |
2.4 gal/max. meal/hour |
| Type "B" | |||
| Drive-ins, grilles, luncheonettes, deli shops | 0.7 gal/max. meal/hour |
6.0 gal/max. meal/hour |
0.7 gal/max. meal/hour |
Hot Water Demand per Fixture Detail Sizing - Kitchens
|
Fixture |
Gallons of water per hour per fixture (calculated at a final temperature of 140ºF) |
| Vegetable sink | 45 |
| Single pot sink | 30 |
| Double pot sink | 60 |
| Triple pot sink | 90 |
| Pre-scrapper (open type) | 180 |
| Pre-flush (hand-operated) | 45 |
| Pre-flush (closed type) | 240 |
| Recirculating pre-flush | 40 |
| Bar sink | 30 |
| Basin, lavatory | 5 |
National Sanitation Foundation NSF Final Rinse Water Requirements for Dishwashing Machines
| Type and sink of dishwasher |
Flow rate |
Hot Water requirements at | |
|
Heaters without |
Heater with | ||
| Door type: | |||
16 X16 |
6.94 | 416 | 69 |
18 X18 |
8.67 | 520 | 87 |
20 X 20 |
10.4 | 624 | 104 |
| Undercounter type | 5 | 300 | 70 |
| Conveyor type: | |||
Single tank |
6.94 | 416 | 416 |
Multiple tank |
5.78 | 347 | 347 |
Multiple tank |
4.62 | 277 | 277 |
Silver washers |
7 | 420 | 45 |
Utensil washers |
8 | 480 | 75 |
Make-up water |
2.31 | 139 | 139 |
Method of Sizing
1. Determine the number of fixtures required for the application and calculate the total hot water demand for those fixture.
Number of Fixtures x Gallons of Water per Hour per Fixture = Possible Maximum Demand
2. Determine the Probable Hot Water Demand for the application.
Probable Hot Water Demand = Possible Maximum Demand x Demand Factor
Demand Factors: Kitchens = 1.00
3. Compare the Probable Hot Water Demand with the 1st Hour Performance Ratings of the Phase III Indirect Water or with the Heat Master Direct Fired Water Heaters.
To convert 180ºF Hot water Demand to 140ºF Hot Water Rating:
180ºF Probable Hot Water Demand x 1.50 = 140ºF 1st. Hour rating